Accessories

Load resistors, cables and much more

You can rent all imaginable accessory items in the field of emergency power technology from us. Check out our load resistors and load banks, power and extension cables, low-voltage main and sub-distribution boards, and NH distribution devices using the following anchor links, and include these in your inquiry directly. In the comprehensive inquiry form, you can conveniently add the desired items.

Accessories

Load resistors, cables and much more

You can rent all imaginable accessory items in the field of emergency power technology from us. Check out our load resistors and load banks, power and extension cables, low-voltage main and sub-distribution boards, and NH distribution devices using the following anchor links, and include these in your inquiry directly. In the comprehensive inquiry form, you can conveniently add the desired items.

Starteinheit für Strom und Wasser

Einfach starten auf der Baustelle mit Strom und Brauchwasser

Die Starteinheit besteht aus einem Aggregat (15 oder 35 kVA), einem Kraftstofftank (1.300 Liter), einer gegen Trockenlaufen gesicherten Wasserpumpe und einem Wassertank. All diese Geräte zur Strom- & Wasserversorgung auf Baustellen befinden sich in einem vandalismusbeständigen, abschließbaren Container mit interner Beleuchtung. Die Starteinheit können Sie über die Blitzanfarge bestellen.

Power cable

Power cables are available in various lengths and diameters in sufficient quantity. Longer lengths can be achieved through combinations using Powerlock connectors or a junction box. It's important to consider potential voltage drop in the case of long cable lengths. If necessary, a generator with higher capacity should be chosen to accommodate this.

LengthCable, number of phases & diameterCable ends
25m Power cable 5 x 4 mm² M8 ferrules
50m Power cable 5 x 4 mm² M8 ferrules
25m Power cable 5 x 16 mm² M10 cable eyes
50m Power cable 5 x 16 mm² M10 cable eyes
25m Power cable 5 x 25 mm² M10 cable eyes
50m Power cable 5 x 25 mm² M10 cable eyes
25m Power cable 5 x 35 mm² M10 cable eyes
50m Power cable 5 x 35 mm² M10 cable eyes
25m Power cable 5 x 50 mm² M10 cable eyes
50m Power cable 5 x 50 mm² M10 cable eyes
30m Power cable 4 x 70 mm² M12 cable eyes
60m Power cable 4 x 70 mm² M12 cable eyes
5m Power cable 4 x 120 mm² M12 cable eyes
10m Power cable 4 x 120 mm² M12 cable eyes
15m Power cable 4 x 120 mm² M12 cable eyes
30m Power cable 4 x 120 mm² M12 cable eyes
60m Power cable 4 x 120 mm² M12 cable eyes
90m Power cable 4 x 120 mm² M12 cable eyes

Extension cable

Extension cables in various lengths and diameters are available in the following sizes and lengths in sufficient quantity. Of course, by combining multiple extension cables, longer lengths can be achieved. It's important to consider potential voltage drop. If necessary, a generator with higher capacity should be chosen to accommodate this.

LengthCable, number of phases & diameterKabel, Stecker/Steckdose
10m 5 x 4 mm² Extension cable 32 A CEE
25m 5 x 4 mm² Extension cable 32 A CEE
50m 5 x 4 mm² Extension cable 32 A CEE
10m 5 x 10 mm² Extension cable 63 A CEE
25m 5 x 10 mm² Extension cable 63 A CEE
50m 5 x 10 mm² Extension cable 63 A CEE
10m 5 x 35 mm² Extension cable 125 A CEE
25m 5 x 35 mm² Extension cable 125 A CEE
50m 5 x 35 mm² Extension cable 125 A CEE

NS main and small distributors

Whether it's 125 A, 63 A, 32 A, 16 A CEE plugs or Schuko plugs: Our wide range of low-voltage main and sub-distribution boards offers you almost every possible combination.

Nr.EntranceExit
1. clamps 6 x 125 A CEE (5-pole)
2 x 63 A CEE
2. clamps 2 x 125 A CEE (5-pole)
8 x 63 A CEE
3. clamps 4 x 125 A CEE (5-pole)
4. clamps 2 x 125 A CEE (5-pole)
2 x 63 A CEE
5. clamps 1 x 125 A CEE (5-pole)
2 x 63 A CEE
5. clamps 1 x 125 A CEE (5-pole)
2 x 63 A CEE
6. clamps 1 x 125 A CEE (5-pole)
1 x 63 A CEE (5-pole)
1 x 32 A CEE (5-pole)
3 x 230 V Schuko
7. clamps 10 x 63 A CEE (5-pole)
8. clamps 4 x 63 A CEE (5-pole)
3 x 230 V Schuko
9. clamps 4 x 63 A CEE (5-pole)
6 x 230 V Schuko
10. clamps 2 x 63 A CEE (5-pole)
2 x 32 A CEE (5-pole)
3 x 230 V Schuko
12. clamps 2 x 63 A CEE (5-pole)
2 x 32 A CEE (5-pole)
2 x 16 A CEE (5-pole)
6 x 230 V Schuko
13. clamps 6 x 32 A CEE (5-pole)
14. clamps 4 x 32 A CEE (5-pole)
3 x 230 V Schuko
15. clamps 2 x 32 A CEE (5-pole)
4 x 16 A CEE (5-pole)
6 x 230 V Schuko
16. clamps 2 x 32 A CEE (5-pole)
2 x 16 A CEE (5-pole)
6 x 230 V Schuko
17. clamps 6 x 16 A CEE (5-pole)
6 x 230 V Schuko
18. 63 A CEE (5-pole) 63 A CEE looped through
2 x 32 A CEE (5-pole)
6 x 230 V Schuko
19. 32 A CEE (5-pole) 32 A CEE looped through
6 x 230 V Schuko
20. 32 A CEE (5-pole) 2 x 16 A CEE A CEE (5-pole)
21. 63 A CEE (5-pole) 2 x 32 A CEE A CEE (5-pole)
22. 125 A CEE (5-pole) 2 x 63 A CEE A CEE (5-pole)

NH distribution facilities

Nr.EntranceExit
1.  clamps 3 x NH DIN 2
4 x NH DIN 00
max. input 630 A
2.  clamps 3 x NH DIN 3
max. input 800 A
3.  clamps 6 x NH DIN 3
max. input 1,250 A
4.  clamps 4 x NH DIN 3
max. input 2,500 A
Nr.SetFuse ( available sizes ) in A
1.  3 x NH 00 6, 10, 16, 20, 25, 32, 35, 40, 50, 63, 80, 100, 125, 160
2.  3 x NH 02 63, 80, 100, 125, 160, 200, 224, 250, 315, 355, 400
3.  3 x NH 03 160,250,400,630,1.250
  • Filter by
  • Cart

  • Filter by price

Showing all 2 results