Self-regenerating filter system.

Details
Self-regenerating filter systems are suitable for applications where high performance and thus high exhaust temperatures are frequently required, such as in combined heat and power plants or peak load systems. Even if the high temperatures are not constantly reached, it is sufficient to regenerate the filter at high temperatures at regular intervals.
The use in emergency power systems is only recommended if it is possible to temporarily raise the exhaust temperature during emergency operation (e.g., in parallel operation with the grid, load resistors).

Construction
Standard version with catalytically coated filter ceramic. Regeneration starts at approximately 400°C.
All filter systems can be equipped with an integrated automatic safety bypass upon request. This enhances operational safety during emergency power operation.

Regeneration
Standard version with catalytically coated filter ceramic. Regeneration starts at approximately 400°C.
All filter systems can be equipped with an integrated automatic safety bypass upon request. This enhances operational safety during emergency power operation.

Maintenance
The systems are largely maintenance-free. During continuous operation, the removal of ash residues is required at longer intervals.

On Request

Request now
Artikelnummer: RPF2 Category:
Type CRP-SK
Regeneration Generally self-acting
Backpressure monitoring
Safety bypass Alternatively
Required exhaust temperature ca. 400 °C
Application area(s) Backup power systems, peak load systems, pump and compressor systems, combined heat and power (CHP) plants.
Version Alternatively with pre-catalyst.
Special features Automatic regeneration, largely maintenance-free.
SKU RPF2

Beschreibung

Details
Self-regenerating filter systems are suitable for applications where high performance and thus high exhaust temperatures are frequently required, such as in combined heat and power plants or peak load systems. Even if the high temperatures are not constantly reached, it is sufficient to regenerate the filter at high temperatures at regular intervals.
The use in emergency power systems is only recommended if it is possible to temporarily raise the exhaust temperature during emergency operation (e.g., in parallel operation with the grid, load resistors).

Construction
Standard version with catalytically coated filter ceramic. Regeneration starts at approximately 400°C.
All filter systems can be equipped with an integrated automatic safety bypass upon request. This enhances operational safety during emergency power operation.

Regeneration
Standard version with catalytically coated filter ceramic. Regeneration starts at approximately 400°C.
All filter systems can be equipped with an integrated automatic safety bypass upon request. This enhances operational safety during emergency power operation.

Maintenance
The systems are largely maintenance-free. During continuous operation, the removal of ash residues is required at longer intervals.

Zusätzliche Informationen

Type CRP-SK
Regeneration Generally self-acting
Backpressure monitoring
Safety bypass Alternatively
Required exhaust temperature ca. 400 °C
Application area(s) Backup power systems, peak load systems, pump and compressor systems, combined heat and power (CHP) plants.
Version Alternatively with pre-catalyst.
Special features Automatic regeneration, largely maintenance-free.
SKU RPF2