350 kVA Stromerzeuger V350C2

Stromerzeuger V350C2


Notice:


Technische Änderungen vorbehalten. Abbildung ähnlich. Sämtliche Modelle, ausgeschlossen alle K-Modelle größer 20 kVA, erfüllen die gesetzlichen Abgasvorschriften für den mobilen Einsatz, entsprechend der EU NON ROAD Richtlinie 2004/26/EG. C2 Modelle sind für den mobilen/ortsveränderlichen Einsatz geeignet.


General description:


The engine and generator of the generator set are elastically mounted on a stable base frame. The assembly consists of a sturdy, multiple-coated weather and soundproof enclosure. The day tank is located in the base frame, which has a closed bottom sump to catch all liquid media of the unit in case of damage. Lockable doors on both sides of the body ensure easy access for maintenance and service.



Control:


The generator control is installed in a control panel and designed for manual and automatic start.

Optional: with engine pre-heating and battery charger for emergency power operation, the network monitor is usually located in a separate control panel with the network and generator protection/circuit breaker.


Power section:


Generator circuit breaker, 3- or 4-pole


Connections:


Cable fixed connection at the circuit breaker

Optional: Socket set depending on capacity (socket 230 V 16 A, socket 400 V 16/32/63 A, or socket 400 V 125 A)


Personal protection (Optional)


ISO monitoring or RCD (Residual Current Device) circuit breaker


Fuel tank:


The fuel filler neck is located above the tank inside the enclosure.

Optional: Extended base frame tanks, double-walled for 18 to 24-hour operation, partially with lifting pipe and forklift pockets.


Chassis (Optional):


Road chassis with height-adjustable drawbar, parking and service brake, welded and galvanized frame, aluminum checker plate fenders, jockey wheel at the front, support legs at the rear, lighting according to German road traffic regulations (STVZO), TÜV/Dekra certification, and operating permit.


Colour (Optional):


Painting in customer-specific color

On Request

Request now
Artikelnummer: SE0024 Category:
Power 400 V (3~) 254,4 kW | 318 kVA
Emergency power output 280 kW | 350 kVA
Power factor cos phi 0.8
Sound pressure 67 dB(A) at 7 m
Fuel Diesel
Tank capacity 470 l (intern)
Consumption per hour ca. 50,6 l (bei 75% Last)
Engine manufacturer Volvo
engine not specified
Speed 1.500 U/min
Dimensions in cm (LxWxH) 448 x 141 x 243
Weight in kg 4.450 kg voll
Version three-phase
Version Standard-Schalttafel TELYS, Wasserkühlung, Lichtmaschine 24 V, Anlasser 24 V und Batterie 24 V
Motor control electronic
Frequency 50 Hz
Environment Exhaust silencer
validation IP 23 protection class
Low oil cut-off No
data sheet here. /media/wysiwyg/PDF/Verkauf/Stromerzeuger/350_kVA_Stromerzeuger_V350C2.pdf
SKU SE0024

Beschreibung

Stromerzeuger V350C2

Notice:

Technische Änderungen vorbehalten. Abbildung ähnlich. Sämtliche Modelle, ausgeschlossen alle K-Modelle größer 20 kVA, erfüllen die gesetzlichen Abgasvorschriften für den mobilen Einsatz, entsprechend der EU NON ROAD Richtlinie 2004/26/EG. C2 Modelle sind für den mobilen/ortsveränderlichen Einsatz geeignet.

General description:

The engine and generator of the generator set are elastically mounted on a stable base frame. The assembly consists of a sturdy, multiple-coated weather and soundproof enclosure. The day tank is located in the base frame, which has a closed bottom sump to catch all liquid media of the unit in case of damage. Lockable doors on both sides of the body ensure easy access for maintenance and service.

Control:

The generator control is installed in a control panel and designed for manual and automatic start.
Optional: with engine pre-heating and battery charger for emergency power operation, the network monitor is usually located in a separate control panel with the network and generator protection/circuit breaker.

Power section:

Generator circuit breaker, 3- or 4-pole

Connections:

Cable fixed connection at the circuit breaker
Optional: Socket set depending on capacity (socket 230 V 16 A, socket 400 V 16/32/63 A, or socket 400 V 125 A)

Personal protection (Optional)

ISO monitoring or RCD (Residual Current Device) circuit breaker

Fuel tank:

The fuel filler neck is located above the tank inside the enclosure.
Optional: Extended base frame tanks, double-walled for 18 to 24-hour operation, partially with lifting pipe and forklift pockets.

Chassis (Optional):

Road chassis with height-adjustable drawbar, parking and service brake, welded and galvanized frame, aluminum checker plate fenders, jockey wheel at the front, support legs at the rear, lighting according to German road traffic regulations (STVZO), TÜV/Dekra certification, and operating permit.

Colour (Optional):

Painting in customer-specific color

Zusätzliche Informationen

Power 400 V (3~) 254,4 kW | 318 kVA
Emergency power output 280 kW | 350 kVA
Power factor cos phi 0.8
Sound pressure 67 dB(A) at 7 m
Fuel Diesel
Tank capacity 470 l (intern)
Consumption per hour ca. 50,6 l (bei 75% Last)
Engine manufacturer Volvo
engine not specified
Speed 1.500 U/min
Dimensions in cm (LxWxH) 448 x 141 x 243
Weight in kg 4.450 kg voll
Version three-phase
Version Standard-Schalttafel TELYS, Wasserkühlung, Lichtmaschine 24 V, Anlasser 24 V und Batterie 24 V
Motor control electronic
Frequency 50 Hz
Environment Exhaust silencer
validation IP 23 protection class
Low oil cut-off No
data sheet here. /media/wysiwyg/PDF/Verkauf/Stromerzeuger/350_kVA_Stromerzeuger_V350C2.pdf
SKU SE0024